BKS - CP1300 defoaming machine

Equipment model and name: BKS - CP1300 defoaming machine |
||
Device configuration |
||
Control system |
PLC controller |
Japan panasonic |
MMI(Touch screen) |
WENVIEW 7〞Color touch screen |
|
Temperature controller |
Japanese mountain force thermostat (PID control) |
|
The temperature control loop |
Fan circulation (external magnetic seal of motor) |
|
Pressure control |
Digital display pressure control table |
|
Waves are stable |
Japan import filter |
|
Temperature controlled action contactor |
Solid state contactless control |
|
Power protection |
30A can reset the leakage switch |
|
The power supply |
DC24V(built-in power supply) |
|
False protection |
Bidirectional interlock design of machine software and hardware |
|
Technical parameters |
Heating mode |
Resistance heating and electromagnetic heating are optional |
Pressure time (constant pressure ~ 6kg) |
8~10min(depending on the location of the gas source) |
|
Pressure time (6kg ~ normal pressure) |
5~8 min |
|
Heating time (at room temperature to 70 ℃) |
5~15min(Depending on the temperature of the cylinder before heating) |
|
Normal temperature range |
RT(Room temperature)-- 80°C |
|
Temperature control precision |
All warm<±3% |
|
Normal pressure setting range |
Set the range 0.1-0.78 mpa |
|
Working medium |
Compressed air, steam |
|
Equipment structure |
Square and channel steel welding, shell baking sheet |
|
Factory site/facility requirements |
The power supply |
380V 50Hz±10% |
The most powerful |
10KW(Resistance heating) |
|
The supply air |
0.5~0.8Mpa(Dry air) |
|
Tracheal specifications |
¢12MM |
|
Operating environment |
Applicable to standard workshop |
|
Cylinder size |
Diameter: ¢1000 mm length: 1500 mm |
|
Installation dimensions |
Approximately (L*W*H)2800*2200*1900mm (not high in trichromatic lamp) |
|
The total weight |
About 1200 kg |
|
Security and protection |
Electrical overvoltage protection |
Detection of overpressure automatic platoon pressure |
Mechanical overpressure protection |
Relief valve automatic discharge pressure |
|
Electrical discharge pressure protection
|
After the exhaust, the cylinder lock is opened and the alarm is issued |
|
Mechanical pressure protection
|
The upper steel pin of the cylinder door falls during low gas |
|
Emergency discharge suppression |
Emergency bypass pressure valve |
|
The action to protect |
The mechanical limit switch and various induction switches are interlocked with the software |
|
Random accessories |
The trachea |
10M/quick joint 1 set |
Job description and pressure volume certificate |
One copy each of the |
Prev:BKS - OLB automatic line | Next:Small size hot pressing bunding machine series |